MS112 allows assessing the technical condition of electric compressors in the air conditioning systems of hybrid cars and electric vehicles. The stand checks the compressor's performance and the functionality of the inverter.
Supply voltage, V | 230 |
Supply mains type | Single-phase |
Demanded power, kW | 3 |
Dimensions (L x W x H), mm | 740×600×550 |
Weight, kg | 40 |
Compressor check | |
Tested units | 2-pin high voltage connection, with built-in inverters |
Tested units supply voltage, VDC | from 200 to 400 |
Working substance | Compressed nitrogen (external source required ) |
The working pressure at the output of the nitrogen cylinder regulator | 7..8 Bar (100..110 psi) |
Nitrogen consumption | 100 normal liters per test |
Required nitrogen flow, l/min | 400 |
Nitrogen recovery | No. Waste gas is discharged into the atmosphere |
Nitrogen connection | SAE 1/4” |
Additional features | |
Software update | Available |
Connection of USB flash drive | USB Type-C |
MS112 allows assessing the technical condition of electric compressors in the air conditioning systems of hybrid cars and electric vehicles. The stand checks the compressor's performance and the functionality of the inverter.
Purpose:
The MS112 stand is designed for diagnosing electric compressors in the air conditioning systems of vehicles with a direct current power supply voltage ranging from 200 to 400 V. Nitrogen is used as the working medium.
The stand offers two diagnostic modes:
Advantages:
• Compressor database.
• The diagnostic process is highly automated.
• Convenient compressor connection using specialized cables and fittings.
• Free software updates.
• Saving and printing of diagnostic results (under development).
Supply voltage, V | 230 |
Supply mains type | Single-phase |
Demanded power, kW | 3 |
Dimensions (L x W x H), mm | 740×600×550 |
Weight, kg | 40 |
Compressor check | |
Tested units | 2-pin high voltage connection, with built-in inverters |
Tested units supply voltage, VDC | from 200 to 400 |
Working substance | Compressed nitrogen (external source required ) |
The working pressure at the output of the nitrogen cylinder regulator | 7..8 Bar (100..110 psi) |
Nitrogen consumption | 100 normal liters per test |
Required nitrogen flow, l/min | 400 |
Nitrogen recovery | No. Waste gas is discharged into the atmosphere |
Nitrogen connection | SAE 1/4” |
Additional features | |
Software update | Available |
Connection of USB flash drive | USB Type-C |