MS004 COМ – multifunctional test bench designed for the quick and the accurate diagnostics of the automotive alternators and starters of the passenger cars and the light commercial vehicles.
Dimensions (L×W×H), mm | 570×505×450 | |
Weight, kg | 70 | |
Supply voltage, V | 230 (60Hz) or 120 (50Hz) | |
Supply type | Single-phase | |
Drive power, kW | 2.2 | |
Quantity of storage batteries (not included into supply slip) | 2 similar lead-acid by 12V | |
Battery capacity | Capacity from 45 up to 60 A-h and dimensions (L x W x H) not exceeding 207×175×175 mm | |
Storage battery automatic charging No.1 | Available | |
Storage battery automatic charging No.2 | Not available | |
Rated voltage of the diagnosed units, V | 12, 24 | |
Alternator diagnostics | ||
Load, A | 12V | 0 – 100 |
24V | 0 – 50 | |
Load adjustment (0-100%) | Smoothly | |
Drive speed, rpm | 0-3000 | |
Drive speed adjustment | Smoothly | |
Drive type (drive/alternator) | Belt | |
Belt types | - V-belt - poly V-belt | |
Types of diagnosed alternators | COM (LIN, BSS), P-D, RLO, C, SIG, F/67 | |
Measured parameters | - Stabilizing voltage; - Alternating current; - Continuous current; - Drive speed; For COM voltage regulators: - Protocol; - Exchange speed; - ID; - Type; - Errors. | |
Voltage regulator diagnostics | ||
Types of diagnosed voltage regulators | COM (LIN, BSS), P-D, RLO, C, SIG | |
Parameters of voltage regulator to be checked | - Stabilizing voltage; - Control of the performance capacity of storage battery indicator lamp circuit (D+) For COM voltage regulators: - Protocol; - Exchange speed; - ID; - Type; - Errors. | |
Short circuit protection | Available | |
Short circuit alarm | Available | |
Starter diagnostics | ||
Power of diagnosed starters, kW | up to 4 | |
Measured parameters | - Voltage; - Alternating current; - Continuous current. |
MS004 COМ – multifunctional test bench designed for the quick and the accurate diagnostics of the automotive alternators and starters of the passenger cars and the light commercial vehicles.
Application:
Features:
Dimensions (L×W×H), mm | 570×505×450 | |
Weight, kg | 70 | |
Supply voltage, V | 230 (60Hz) or 120 (50Hz) | |
Supply type | Single-phase | |
Drive power, kW | 2.2 | |
Quantity of storage batteries (not included into supply slip) | 2 similar lead-acid by 12V | |
Battery capacity | Capacity from 45 up to 60 A-h and dimensions (L x W x H) not exceeding 207×175×175 mm | |
Storage battery automatic charging No.1 | Available | |
Storage battery automatic charging No.2 | Not available | |
Rated voltage of the diagnosed units, V | 12, 24 | |
Alternator diagnostics | ||
Load, A | 12V | 0 – 100 |
24V | 0 – 50 | |
Load adjustment (0-100%) | Smoothly | |
Drive speed, rpm | 0-3000 | |
Drive speed adjustment | Smoothly | |
Drive type (drive/alternator) | Belt | |
Belt types | - V-belt - poly V-belt | |
Types of diagnosed alternators | COM (LIN, BSS), P-D, RLO, C, SIG, F/67 | |
Measured parameters | - Stabilizing voltage; - Alternating current; - Continuous current; - Drive speed; For COM voltage regulators: - Protocol; - Exchange speed; - ID; - Type; - Errors. | |
Voltage regulator diagnostics | ||
Types of diagnosed voltage regulators | COM (LIN, BSS), P-D, RLO, C, SIG | |
Parameters of voltage regulator to be checked | - Stabilizing voltage; - Control of the performance capacity of storage battery indicator lamp circuit (D+) For COM voltage regulators: - Protocol; - Exchange speed; - ID; - Type; - Errors. | |
Short circuit protection | Available | |
Short circuit alarm | Available | |
Starter diagnostics | ||
Power of diagnosed starters, kW | up to 4 | |
Measured parameters | - Voltage; - Alternating current; - Continuous current. |