TEST BENCH MSG MS004 COM

Test bench for quick and quality diagnostics of starters, alternators and voltage regulators without applying any additional measuring devices. The test bench has dimensions and can be placed on a table. Besides, it possess high power, thus, units can be diagnosed under different loads. The bench includes the following diagnostic functions: testing of 12V and 24V alternators under load, 12V and 24V voltage regulators, 12V and 24V starters in idle running mode. The device carries out testing of different alternators under load up to 100A. Power supply is single-phase 220V.

This equipment is CE certified! 

The equipment set includes:

  • test bench
  • 2 cables for external battery connection
  • wires to connect an alternator, starter, voltage regulator to the bench sockets
  • user manual
  • product certificate

More details

Price by request

TECHNICAL CHARACTERISTICS
Supply voltage, V230±10% or 110±10%
Voltage of tested electromagnetic valves, V12/24
Drive power, kW2,2
Load, A0-100
Load adjustmentSmoothly
Drive rotation, rpm0-3000
Drive rotation directionLeft/right
Drive rotation adjustmentSmoothly
Transmission type (drive/alternator)Belt
Belt typeBelt; Poly-V belt
Read parameters of unitsVoltage; alternating current; constant current; drive rotation. COM voltage regulators: protocol; speed of exchange; protocol type; errors
Voltage of tested starters, V12/24
Power of tested starters, kWUp to 4
Measured parametersVoltage; alternating current; сonstant current
Voltage of tested voltage regulators, V12/24
Tested parameters of voltage regulatorsStabilizing voltage; current rotor winding. COM voltage regulators: protocol; speed of exchange; regulator type; errors
Voltage measurement accuracy, V0,1
Current measurement accuracy, A0,1
Short circuit protection
Short circuit sound alertYes
Terminals of tested regulatorsCOM, P-D, DFM, D+, RLO, C, SIG
Total check of voltage regulator, sec30
Weight, kg70
Dimensions, W×D×H, mm570*490*450
ATTACHMENTS
More info

How to test starters?

  1. Install a starter on the mounting face.
  2. Release the chain to the required length, latch the chain over the chain fixer of the mounting face.
  3. Fix the unit on the mounting face. Tightening will stop automatically.
  4. Connect the power cable B- with multifunctional tightening, called ‘crocodile’, to the body of the tested unit, which is earth, connected to negative terminal of the battery.
  5. Press the button Alternator & Starter tester, set required voltage with 12V/24V buttons, according to the technical characteristics of a tested starter.
  6. Connect B+wire to the power terminal of a starter.
  7. Connect 50 socket to the power terminal of starter solenoid.
  8. Press START button. A faultless starter will switch on at once.
  9. Follow the indicators of current and voltage characteristics.

On finishing testing of a starter:

  1. Deactivate testing mode with Alternator & starter tester button.
  2. Disconnect the wires from a starter.
  3. Releasethefixingchain.
  4. Remove a starter from the mountingface.

Find detailed step-by-step instruction on how to test alternators and voltage regulators in 'ATTACHMENTS' to this product.

6 other products in the same category:
Request price
Request send